Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
1.
Urolithiasis ; 52(1): 57, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38563829

RESUMO

Calcium oxalate kidney stones, the most prevalent type of kidney stones, undergo a multi-step process of crystal nucleation, growth, aggregation, and secondary transition. The secondary transition has been rather overlooked, and thus, the effects on the disease and the underlying mechanism remain unclear. Here, we show, by periodic micro-CT images of human kidney stones in an ex vivo incubation experiment, that the growth of porous aggregates of calcium oxalate dihydrate (COD) crystals triggers the hardening of the kidney stones that causes difficulty in lithotripsy of kidney stone disease in the secondary transition. This hardening was caused by the internal nucleation and growth of precise calcium oxalate monohydrate (COM) crystals from isolated urine in which the calcium oxalate concentrations decreased by the growth of COD in closed grain boundaries of COD aggregate kidney stones. Reducing the calcium oxalate concentrations in urine is regarded as a typical approach for avoiding the recurrence. However, our results revealed that the decrease of the concentrations in closed microenvironments conversely promotes the transition of the COD aggregates into hard COM aggregates. We anticipate that the suppression of the secondary transition has the potential to manage the deterioration of kidney stone disease.


Assuntos
Líquidos Corporais , Cálculos Renais , Litotripsia , Humanos , Oxalato de Cálcio , Dureza
3.
J Surg Oncol ; 2024 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-38470556

RESUMO

BACKGROUND AND OBJECTIVES: We aimed to examine the effect of preoperative three-dimensional (3D) computed tomography (CT)-based resection process map (RPM) imaging on the outcomes of robot-assisted partial nephrectomy (RAPN). METHODS: We retrospectively analyzed 177 patients (RPM group, n = 92; non-RPM group, n = 85) who underwent this surgery between November 2012 and April 2022. Patient-specific contrast-enhanced CT images were used to construct an RPM, a 3D representation of the kidney showing the planned tumor resection and a 5 mm safety margin. Outcome analyses were performed using propensity score matching. The primary endpoint was the trifecta achievement rate. RESULTS: We extracted 90 cases. The trifecta achievement rate showed no significant differences between the RPM (73.3%) and non-RPM groups (73.3%). However, the RPM group had fewer Grade 3 and higher complications (0.0% vs. 13.3%, p = 0.026). The da Vinci Xi (OR 3.38, p = 0.016) and tumor diameter (OR 0.95, p = 0.013) were independent factors affecting trifecta achievement in multivariate analysis. Using RPM imaging was associated with the absence of Grade 3 and higher perioperative complications (OR 5.33, p = 0.036) in univariate analysis. CONCLUSIONS: Using preoperative 3D CT-based RPM images before RAPN may not affect trifecta achievement, but may reduce serious complication occurrence by providing detailed information on tumor resection.

4.
Urolithiasis ; 52(1): 51, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38554162

RESUMO

Macrophages play a role in nephrolithiasis, offering the possibility of developing macrophage-mediated preventive therapies. To establish a system for screening drugs that could prevent the formation of kidney stones, we aimed to develop a model using human induced pluripotent stem cell (iPSC)-derived macrophages to study phagocytosis of calcium oxalate monohydrate (COM) crystals. Human iPSCs (201B7) were cultured. CD14+ monocytes were recovered using a stepwise process that involved the use of growth factors and cytokines. These cells were then allowed to differentiate into M1 and M2 macrophages. The macrophages were co-cultured with COM crystals and used in the phagocytosis experiments. Live cell imaging and polarized light observation via super-resolution microscopy were used to visualize phagocytosis. Localization of phagocytosed COM crystals was observed using transmission electron microscopy. Intracellular fluorescence intensity was measured using imaging cytometry to quantify phagocytosis. Human iPSCs successfully differentiated into M1 and M2 macrophages. M1 macrophages adhered to the culture plate and moved COM crystals from the periphery to cell center over time, whereas M2 macrophages did not adhere to the culture plate and actively phagocytosed the surrounding COM crystals. Fluorescence assessment over a 24-h period showed that M2 macrophages exhibited higher intracellular fluorescence intensity (5.65-times higher than that of M1 macrophages at 4.5 h) and maintained this advantage for 18 h. This study revealed that human iPSC-derived macrophages have the ability to phagocytose COM crystals, presenting a new approach for studying urinary stone formation and highlighting the potential of iPSC-derived macrophages as a tool to screen nephrolithiasis-related drugs.


Assuntos
Células-Tronco Pluripotentes Induzidas , Cálculos Renais , Humanos , Oxalato de Cálcio/metabolismo , Células-Tronco Pluripotentes Induzidas/metabolismo , Macrófagos/metabolismo , Fagocitose , Cálculos Renais/metabolismo
5.
IJU Case Rep ; 7(2): 101-104, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38440712

RESUMO

Introduction: The bladder exstrophy-epispadias complex is a rare congenital disease. Urothelial carcinomas rarely occur in patients with this disease, and there have been few reports on its treatment. Case presentation: We report the case of a 44-year-old man with a hemorrhage from the external urethral meatus. He was diagnosed with bladder exstrophy-epispadias complex and underwent urinary diversion with substitution cystoplasty and Mitrofanoff appendicovesicostomy. Because computed tomography and magnetic resonance imaging suggested invasive bladder carcinoma in the defunctionalized bladder, we performed a cystectomy. The patient was diagnosed with urothelial carcinoma with glandular differentiation. One month after the surgery, nivolumab adjuvant chemotherapy was administered. The patient showed no signs of recurrence or metastasis after the treatment. Conclusion: This is the first case of adjuvant nivolumab therapy for urothelial carcinoma with the bladder exstrophy-epispadias complex.

6.
Ann Thorac Surg ; 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38382704

RESUMO

BACKGROUND: Selection of transcatheter valve size using preprocedural computed tomography (CT) is standardized and well established. However, valve sizing for surgical aortic valve replacement (SAVR) is currently performed intraoperatively by using sizers, which may result in variation among operators and risk for prosthesis-patient mismatch. This study evaluated the usefulness of CT annulus measurement for SAVR valve sizing. METHODS: This study included patients who underwent SAVR using Inspiris or Magna Ease and received preoperative electrocardiogram-gated CT imaging. Starting from June 2022, study investigators applied a CT sizing algorithm using CT-derived annulus size to guide minimum SAVR label size. The final decision of valve selection was left to the operating surgeon during SAVR. The study compared the appropriateness of valve selection (comparing implanted size with CT-predicted size) and prosthesis-patient mismatch rates without aortic root enlargement between 2 cohorts: 102 cases since June 2022 (CT sizing cohort) and 180 cases from 2020 to 2021 (conventional sizing cohort). RESULTS: Implanted size smaller than CT predicted size and severe prosthesis-patient mismatch were significantly lower by CT sizing than by conventional sizing (12% vs 31% [P = .001] and 0% vs 6% [P = .039], respectively). Interoperator variability was a factor associated with implanted size smaller than CT predicted with conventional sizing, whereas it became nonsignificant with CT sizing. CONCLUSIONS: Applying CT sizing to SAVR led to improved valve size selection, less prosthesis-patient mismatch, and less interoperator variability. CT sizing for SAVR could also be used to predict prosthesis-patient mismatch before SAVR and identify patients who need aortic root enlargement.

7.
J Endourol ; 38(2): 186-192, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38009198

RESUMO

Purpose: To evaluate the efficacy of supine percutaneous renal access by robot-assisted (RA) fluoroscopy and ultrasound (US) guidance in terms of procedural outcomes and surgeon workload. Methods: We conducted a multicenter, randomized, controlled benchtop study involving 32 urologists using a renal phantom model. RA puncture was performed using the developed version of automated needle targeting with X-ray (ANT-X), which determines the direction of the needle. US puncture was performed under US guidance. The primary endpoint was the single-puncture success rate, and the secondary outcomes were the procedural time for each step, time of fluoroscopic exposure, and workload assessment. Results: The single-puncture success rates were 90.6% and 56.3% for RA and US punctures, respectively (p < 0.01). In RA puncture, the median device setup time was 120 seconds longer, the median total procedural time was 100 seconds longer, the median time of fluoroscopic exposure was 40 seconds longer, the median needle puncture time was 17 seconds shorter, and the distance from the target sphere was 1 cm shorter than those in US puncture (all p < 0.01). The mental and physical task workload, effort required by the surgeons, frustration felt by the surgeons, and overall National Aeronautics and Space Administration Task Load Index scores were lower in the RA puncture group than in the US puncture group (p = 0.01, p = 0.046, p < 0.01, p = 0.021, and p ≤ 0.01, respectively). Conclusions: RA puncture using ANT-X, which can also be used for puncture in the supine position, offers advantages over renal puncture in terms of accuracy and surgical workload.


Assuntos
Cálculos Renais , Robótica , Estados Unidos , Humanos , Cálculos Renais/cirurgia , Estudos Prospectivos , Rim/diagnóstico por imagem , Rim/cirurgia , Fluoroscopia/métodos
8.
J Cardiol ; 83(3): 169-176, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37543193

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) for severe symptomatic aortic stenosis (AS) does not benefit all patients. We performed a prospective multicenter study to investigate the cost-effectiveness of TAVR in a Japanese cohort. METHODS AND RESULTS: We prospectively enrolled 110 symptomatic patients with severe AS who underwent TAVR from five institutions. The quality of life measurement (QOL) was performed for each patient before and at 6 months after TAVR. Patients without an improvement in QOL at 6 months after TAVR were defined as non-responders. Pre-TAVR higher QOL, higher clinical frailty scale predicted the non-responders. Three models, 1) conservative treatment for all patients strategy, 2) TAVR for all patients strategy, and 3) TAVR for a selected patient strategy who is expected to be a responder, were simulated. Lifetime cost-effectiveness was estimated using incremental cost-effectiveness ratio (ICER) and cost per quality-adjusted life-year (QALY) gained. In comparison to conservative therapy for all patients, ICER was estimated to be 5,765,800 yen/QALY for TAVR for all patients and 2,342,175 yen/QALY for TAVR for selected patient strategy patients, which is less than the commonly accepted ICER threshold of 5,000,000 yen/QALY. CONCLUSIONS: TAVR for selected patient strategy model is more cost-effective than TAVR for all patient strategy without reducing QOL in the Japanese healthcare system. TAVR for selected patient strategy has potential benefit for optimizing the TAVR treatment in patients with high frailty and may direct our resources toward beneficial interventions.


Assuntos
Estenose da Valva Aórtica , Fragilidade , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/métodos , Qualidade de Vida , Análise Custo-Benefício , Estudos Prospectivos , Fragilidade/etiologia , Estenose da Valva Aórtica/etiologia , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Aórtica/cirurgia , Fatores de Risco
9.
J Clin Med ; 12(24)2023 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-38137795

RESUMO

BACKGROUND: Ureteral stricture (US) postureteroscopic lithotripsy (URSL) has emerged as a severe complication with the widespread use of laser technology. Furthermore, managing a complex US is challenging. Therefore, this study evaluated the efficacy of robot-assisted ureteroureterostomy (RAUU) in addressing US post-URSL and analyzed the pathology of transected ureteral tissues to identify the risk factors for US. METHODS: we conducted a prospective cohort study on patients who underwent RAUU for URSL-induced US from April 2021 to May 2023. RESULTS: A total of 14 patients with a mean age of 49.8 years were included in this study. The mean stricture length on radiography was 22.66 ± 7.38 mm. Nine (64.2%) patients had experienced failure with previous interventions. The overall success rate was 92.9%, both clinically and radiographically, without major complications, at a mean follow-up of 12.8 months. The pathological findings revealed microcalcifications and a loss of ureteral mucosa in 57.1% and 28.6% of patients, respectively. CONCLUSIONS: The RAUU technique shows promise as a viable option for US post-URSL in appropriately selected patients despite severe pathological changes in the ureter. Therefore, the migration of microcalcifications to the site of ureteral perforation may be a significant factor contributing to US development.

10.
Artigo em Inglês | MEDLINE | ID: mdl-37921717

RESUMO

BACKGROUND: Quantification of myocardial changes in severe aortic stenosis (AS) is prognostically important. The potential for comprehensive myocardial assessment pre-transcatheter aortic valve replacement (TAVR) by computed tomography angiography (CTA) is unknown. OBJECTIVES: The study sought to evaluate whether quantification of left ventricular (LV) extracellular volume-a marker of myocardial fibrosis-and global longitudinal strain-a marker of myocardial deformation-at baseline CTA associate with post-TAVR outcomes. METHODS: Consecutive patients with symptomatic severe AS between January 2021 and June 2022 who underwent pre-TAVR CTA were included. Computed tomography extracellular volume (CT-ECV) was derived from septum tracing after generating the 3-dimensional CT-ECV map. Computed tomography global longitudinal strain (CT-GLS) used semi-automated feature tracking analysis. The clinical endpoint was the composite outcome of all-cause mortality and heart failure hospitalization. RESULTS: Among the 300 patients (80.0 ± 9.4 years of age, 45% female, median Society of Thoracic Surgeons Predicted Risk of Mortality score 2.80%), the left ventricular ejection fraction (LVEF) was 58 ± 12%, the median CT-ECV was 28.5% (IQR: 26.2% to 32.1%), and the median CT-GLS was -20.1% (IQR: -23.8% to -16.3%). Over a median follow-up of 16 months (IQR: 12 to 22 months), 38 deaths and 70 composite outcomes occurred. Multivariable Cox proportional hazards model, accounting for clinical and echocardiographic variables, demonstrated that CT-ECV (HR: 1.09 [95% CI: 1.02-1.16]; P = 0.008) and CT-GLS (HR: 1.07 [95% CI: 1.01-1.13]; P = 0.017) associated with the composite outcome. In combination, elevated CT-ECV and CT-GLS (above median for each) showed a stronger association with the outcome (HR: 7.14 [95% CI: 2.63-19.36]; P < 0.001). CONCLUSIONS: Comprehensive myocardial quantification of CT-ECV and CT-GLS associated with post-TAVR outcomes in a contemporary low-risk cohort with mostly preserved LVEF. Whether these imaging biomarkers can be potentially used for the decision making including timing of AS intervention and post-TAVR follow-up will require integration into future clinical trials.

11.
Circ Cardiovasc Interv ; 16(11): e013497, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37988440

RESUMO

BACKGROUND: Our aim was to assess the feasibility of repeat transcatheter aortic valve (TAV) replacement for degenerated Sapien3 (S3) prostheses by simulating subsequent implantation of S3 or Evolut, using in vivo computed tomography-based sizing and the impact on coronary and patient-prosthesis mismatch risks. METHODS: Computed tomography scans from 356 patients with prior S3 TAV replacement implantation were analyzed. The in vivo sizing for second TAV based on averaged area of 3 levels of outflow, mid (narrowest) and inflow, was compared with in vitro recommendations, that is, same size as index S3 for second S3 and 1 size larger for Evolut. Risks of coronary obstruction and patient-prosthesis mismatch were determined by valve-to-aorta distance and estimated effective orifice area, respectively. RESULTS: Overall, the majority of patients (n=328; 92.1%) had underexpanded index S3 with an expansion area of 94% (91%-97%), leading to significant differences in size selection of the second TAV between in vivo and in vitro sizing strategies. Expansion area <89% served as a threshold, resulting in 1 size smaller than the in vitro recommendations were selected in 45 patients (13%) for S3-in-S3 and 13 (4%) for Evolut-in-S3, while the remaining patients followed in vitro recommendations (P<0.01, in vivo versus in vitro sizing). Overall, 57% of total patients for S3-in-S3 simulation and 60% for Evolut-in-S3 were considered low risk for coronary complications. Deep index S3 implantation (odds ratio, 0.76 [interquartile range, 0.67-0.87]; P<0.001) and selecting Evolut as the second TAV (11% risk reduction in intermediate- or high-risk patients) reduced coronary risk. Estimated moderate or severe patient-prosthesis mismatch risk was 21% for S3-in-S3 and 1% for Evolut-in-S3, assuming optimal expansion of the second TAV. CONCLUSIONS: Redo-TAV replacement with S3-in-S3 and Evolut-in-S3 could be feasible with low risk to coronaries in ≈60% of patients, while the remaining 40% will be at intermediate or high risk. The feasibility of redo-TAV replacement is influenced by sizing strategy, type of second TAV, native annular anatomy, and implant depth.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos de Viabilidade , Resultado do Tratamento , Desenho de Prótese , Tomografia Computadorizada por Raios X
12.
Diagnostics (Basel) ; 13(20)2023 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-37891994

RESUMO

BACKGROUND: The aim was to investigate the incidence and clinical predictive factors of de novo overactive bladder (OAB) after robot-assisted radical prostatectomy (RARP), including a Retzius-sparing (RS) approach, in the same period at a single institution. METHODS: Of a total of 113 patients with localized prostate cancer, 81 received conventional RARP (CON-RARP) and 32 received RS-RARP at our institution. The basic characteristics data of patients and self-assessment questionnaires, including IPSS and OABSS, were obtained preoperatively and 1, 3, and 6 months after RARP. In addition, a retrospective biomarker analysis was also performed of predictive clinical parameters obtained from cystography that included a postoperative bladder neck to pubic symphysis (BNPS) ratio. RESULTS: Patients' basic characteristics were similar between CON-RARP and RS-RARP groups. With respect to the surgical procedure, anastomosing time was found to be significantly longer for patients in the RS-RARP compared to the CON-RARP group (p < 0.01). Compared to the CON-RARP group, the RS-RARP group showed a significantly lower postoperative BNPS and aspect ratio (p < 0.001). The incidence of de novo OAB in patients of the CON-RARP group was greater than for those in the RS-RARP group (40.7% CON-RARP vs. 25.0% RS-RARP), though this was not significant. Regarding the emergence of de novo OAB, the following were revealed in univariate analysis to be independent prognostic factors: age > 64 years (hazards ratio [HR]: 4.32, 95% confidence interval [CI]: 1.51-12.3), postoperative BNPS ratio > 0.44 (HR: 8.7, 95% CI: 6.43-54.5), postoperative aspect ratio > 1.18 (HR: 3.36, 95% CI: 1.49-7.61). Additionally, multivariate analysis identified a sole significant prognostic factor: postoperative BNPS ratio > 0.44 (HR: 13.3, 95% CI: 4.33-41.1). CONCLUSION: Our findings indicate that the postoperative BNPS ratio may be a practical predictive indicator of the emergence of de novo OAB after RARP.

13.
EuroIntervention ; 19(11): e937-e947, 2023 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-37899719

RESUMO

BACKGROUND: The use of oversizing in mitral valve-in-valve (MViV) procedures can lead to non-uniform expansion of transcatheter heart valves (THV). This may have implications for THV durability. AIMS: The objective of this study was to assess the extent and predictors of THV deformation in MViV procedures. METHODS: We examined 33 patients who underwent MViV with SAPIEN prostheses. The extent of THV deformation (deformation index, eccentricity, neosinus volume, asymmetric leaflet expansion and vertical deformation) and hypoattenuating leaflet thickening (HALT) were assessed using cardiac computed tomography (CT), performed prospectively at 30 days post-procedure. For descriptive purposes, the THV deformation index was calculated, with values >1.00 representing a more hourglass shape. RESULTS: Non-uniform underexpansion of THV was common after MViV implantation, with a median expansion area of 74.0% (interquartile range 68.1-84.1) at the narrowest level and a THV deformation index of 1.21 (1.13-1.29), but circularity was maintained with eccentricity ranging from 0.24 to 0.28. The degree of oversizing was a key factor associated with greater underexpansion and a higher deformation index (ß=-0.634; p<0.001; ß=0.594; p<0.001, respectively). Overall, the incidence of HALT on the 30-day postprocedural CT was 27.3% (9 of 33). Most patients (32 of 33) were on anticoagulation therapy, but the prothrombin time and international normalised ratio (PT-INR) at the time of the CT scan was <2.5 in 23 of 32 patients. Among patients with a PT-INR of <2.5, HALT was predominantly observed with a high THV deformation index of ≥1.18. CONCLUSIONS: THV deformation, i.e., underexpansion and an hourglass shape, commonly occurs after MViV implantation and is negatively affected by excessive oversizing. Optimising THV expansion during MViV could potentially prevent HALT.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Resultado do Tratamento , Desenho de Prótese , Valva Aórtica/cirurgia
14.
Urolithiasis ; 51(1): 113, 2023 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-37707652

RESUMO

We aimed to evaluate the impact of surgical treatment for urinary stones on perioperative health-related quality of life (HRQOL) using the Japanese Wisconsin Stone Quality of Life questionnaire (J-WISQOL), an HRQOL measure designed for patients with urinary stones. This study prospectively enrolled 123 patients with urinary stones who visited three academic hospitals for stone treatment. The participants completed the J-WISQOL within 4 weeks before and after the urinary stone treatment. Treatments included shock wave lithotripsy (SWL), ureteroscopy lithotripsy, and endoscopic combined intrarenal surgery. J-WISQOL was assessed for age, stone size and location, type of treatment, stone-free status, postoperative ureteral stent placement, hospital stay, and complications in all patients. Patients with stones in the ureter had significantly greater social impact D1 and disease impact D3 than those with stones in the kidney. In a comparison of pre- and postoperative J-WISQOL, patients without postoperative ureteral stent placement scored significantly higher on social impact D1 and disease impact D3. Patients with shorter hospital stays had significantly higher social impact D1 and disease impact D3 (p < 0.001) than those with longer hospital stays. SWL significantly improved the total score, social impact D1, and disease impact D3 compared with other treatments. Perioperative HRQOL in patients with urinary stones is particularly affected by the type of treatment, ureteral stent placement, and hospital stay, which should be considered in surgical selection and patient decision-making.


Assuntos
Qualidade de Vida , Cálculos Urinários , Urolitíase , Humanos , Cálculos Urinários/cirurgia , Urolitíase/cirurgia , Inquéritos e Questionários
15.
J Am Heart Assoc ; 12(16): e029717, 2023 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-37581389

RESUMO

Background Prognostic implications of transcatheter aortic valve implantation (TAVI) in low-gradient (LG) aortic stenosis (AS) remain controversial. The authors hypothesized that differences in cardiac functional recovery may solve this ongoing controversy. The aim was to evaluate clinical outcomes and the response of left ventricular (LV) function following TAVI in patients with LG AS. Methods and Results This multicenter retrospective study included 1742 patients with severe AS undergoing TAVI between January 2015 and March 2019. Patients were subdivided into low-flow (LF) LG, normal-flow (NF) LG, LF high-gradient, and NF high-gradient AS groups according to the mean gradient of the aortic valve (LG <40 mm Hg) and LV stroke volume index (LF <35 mL/m2). Outcomes and changes in echocardiographic parameters after TAVI were compared between the groups. A total of 227 patients (13%) had reduced ejection fraction, and 486 patients (28%) had LG AS (LF-LG 143 [8%]; NF-LG 343 [20%]). During a median follow-up period of 747 days, 301 patients experienced a composite end point of cardiovascular death and rehospitalization for cardiovascular events, which was higher in the LF-LG and NF-LG groups than in the high-gradient groups. LG AS was independently associated with the primary outcome (hazard ratio, 1.69; P<0.001). Among 1239 patients with follow-up echocardiography, LG AS showed less improvement in the LV mass index and LV end-diastolic volume compared with high-gradient AS after 1 year, while LV recovery was similar between the LF AS and NF AS groups. Conclusions LG AS was associated with poorer outcomes and LV recovery, regardless of flow status after TAVI. Careful evaluation of AS severity may be required in LG AS to provide TAVI within the appropriate time and advanced care afterward.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Função Ventricular Esquerda/fisiologia , Volume Sistólico/fisiologia , Implante de Prótese de Valva Cardíaca/métodos , Índice de Gravidade de Doença
16.
Int J Urol ; 30(10): 866-874, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37278575

RESUMO

OBJECTIVES: Ipilimumab and nivolumab treatment against advanced and metastatic renal cell carcinoma (RCC) causes severe and lethal immune-related adverse events (irAEs). Predicting irAEs might improve clinical outcomes, however no practical biomarkers exist. This study examined whether eosinophils could be effective biomarkers for ≥grade 2 irAEs in RCC. METHODS: We retrospectively analyzed 75 patients with RCC treated with ipilimumab and nivolumab between August 2018 and March 2021 in a multicenter study. Eosinophils were examined before and 2 weeks after treatment, and immediately after irAEs development. The optimal cut-off value for ≥grade 2 irAEs was determined by a receiver operating characteristic (ROC) curve. Univariate and multivariate analyses were undertaken to identify predictors of ≥grade 2 irAEs. RESULTS: Two weeks after treatment, eosinophils were significantly upregulated in patients who had experienced ≥grade 2 irAEs than in those who had not experienced irAEs (mean, 5.7% vs. 3.2%; p < 0.05). The optimal cut-off value for eosinophils against ≥grade 2 irAEs was 3.0% (area under the curve = 0.69). In multivariate analyses, an eosinophil level ≥ 3.0% was a risk factor for ≥grade 2 irAEs (odds ratio 4.18, 95% confidence interval 1.16-15.1). The eosinophil level 2 weeks after treatment was upregulated by the onset of any type of irAEs including endocrine, gastrointestinal, pulmonary and skin disorders. CONCLUSIONS: An increased eosinophil level 2 weeks after treatment might be an effective biomarker for ≥grade 2 irAEs in patients with RCC treated with ipilimumab and nivolumab.


Assuntos
Antineoplásicos Imunológicos , Carcinoma de Células Renais , Neoplasias Renais , Melanoma , Humanos , Nivolumabe/efeitos adversos , Ipilimumab/efeitos adversos , Carcinoma de Células Renais/tratamento farmacológico , Eosinófilos/patologia , Melanoma/tratamento farmacológico , Melanoma/induzido quimicamente , Estudos Retrospectivos , Antineoplásicos Imunológicos/efeitos adversos , Neoplasias Renais/tratamento farmacológico , Neoplasias Renais/patologia , Biomarcadores
17.
BMC Cardiovasc Disord ; 23(1): 281, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-37264308

RESUMO

BACKGROUND: Recent studies have reported atrial involvement and coexistence of aortic stenosis in transthyretin (ATTR) cardiac amyloidosis (CA). However, pathological reports of extraventricular ATTR amyloid deposits in atrial structures or heart valves are limited, and the clinical implications of ATTR amyloid deposits outside the ventricles are not fully elucidated. CASE PRESENTATION: We report 3 cases of extraventricular ATTR amyloid deposits confirmed in surgically resected aortic valves and left atrial structures, all of which were unlikely to have significant ATTR amyloidosis infiltrating the ventricles as determined by multimodality evaluation including 99mtechnetium-pyrophosphate scintigraphy, cardiac magnetic resonance, endomyocardial biopsy and their mid-term clinical course up to 5 years. These findings suggested that these were extraventricular ATTR amyloid deposits localized in the aortic valve and the left atrium. CONCLUSIONS: While long-term observation is required to fully clarify whether these extraventricular ATTR amyloid deposits are truly localized outside the ventricles or are early stages of ATTR-CA infiltrating the ventricles, our 3 cases with multimodality evaluations and mid-term follow up suggest the existence of extraventricular ATTR amyloid deposits localized in the aortic valve and left atrial structures.


Assuntos
Neuropatias Amiloides Familiares , Fibrilação Atrial , Cardiomiopatias , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Neuropatias Amiloides Familiares/diagnóstico por imagem , Seguimentos , Placa Amiloide , Pré-Albumina/genética , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiomiopatias/diagnóstico por imagem
18.
Int J Urol ; 30(9): 754-761, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37150513

RESUMO

OBJECTIVE: To identify biomarkers associated with the effectiveness of ipilimumab plus nivolumab against advanced metastatic renal cell carcinoma. METHODS: We retrospectively analyzed the data of 75 patients treated with ipilimumab plus nivolumab at seven hospitals between August 2018 and April 2021. Prognostic biomarkers were assessed prior to initiating treatment with ipilimumab plus nivolumab. Median overall survival and progression-free survival were examined using the Kaplan-Meier method. Univariate and multivariate analyses were performed to identify predictors of disease progression. The International Metastatic Renal Cell Carcinoma Database Consortium (IMDC) risk factors most important for predicting disease progression were determined using classification and regression tree analysis. RESULTS: Median overall survival and progression-free survival were longer in the intermediate IMDC risk group than in the poor IMDC risk group (overall: not reached vs. 18.3 months; progression-free: not reached vs. 13.5 months). The multivariate analysis identified poor IMDC risk as a risk factor for disease progression (hazard ratio 2.61, 95% confidence interval: 1.05-6.51). Based on the results of the classification and regression tree analysis, the cohort was divided into non-anemia, anemia + neutro-Low, and anemia + neutro-High groups. Median overall survival and progression-free survival were longer in the non-anemia and anemia + neutro-Low groups than in the anemia + neutro-High group (overall: not reached vs. 29.3 months vs. 4.3 months: progression-free: not reached vs. 29.0 months vs. 3.9 months). CONCLUSION: Hemoglobin and neutrophil levels may represent crucial biomarkers for predicting the effectiveness of ipilimumab plus nivolumab therapy in patients with renal cell carcinoma.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Carcinoma de Células Renais/patologia , Nivolumabe/uso terapêutico , Ipilimumab/uso terapêutico , Ipilimumab/efeitos adversos , Neoplasias Renais/patologia , Estudos Retrospectivos , Neutrófilos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Progressão da Doença , Hemoglobinas/uso terapêutico
19.
Artigo em Inglês | MEDLINE | ID: mdl-36934788

RESUMO

We aimed to investigate the prevalence and predictors of postoperative tricuspid regurgitation (TR) worsening in patients with mitral regurgitation (MR) and concomitant ≤mild TR. A total of 620 patients underwent surgery for MR from 2013 to 2017. Of these, 260 had ≤mild preoperative TR and no concomitant tricuspid valve surgery and were enrolled in this single-center retrospective study. The primary endpoint was postoperative worsening of ≥moderate TR. The primary endpoint occurred in 28 of 260 patients (11%) during the follow-up period [median: 4.1 years (interquartile range: 2.9-6.1 years)]. In the multivariable analysis, age, female sex, and left atrial volume index (LAVI) were significant predictors of the primary outcome during intermediate-term follow-up (age: hazard ratio [HR] 1.05 per 1-year increment, 95% confidence interval [CI] 1.02-1.10, P = 0.003; female sex: HR 3.53, 95% CI 1.61-7.72, P = 0.002; LAVI: HR 1.17 per 10-mL/m2 increment, 95% CI 1.07-1.26, P < 0.001). The optimal LAVI cut-off value for predicting postoperative TR worsening was 79 mL/m2 (area under the curve: 0.69). A high LAVI (>79 mL/m²) was significantly associated with a low rate of freedom from postoperative TR worsening compared with a low LAVI (≤79 mL/m²) (82.6% vs 93.9% at 5 years, respectively; log-rank P = 0.008). In patients with ≤mild preoperative TR and no concomitant tricuspid surgery, the rate of postoperative TR worsening was 11% during intermediate-term follow-up. LA enlargement in patients with MR and ≤mild preoperative TR was significantly associated with postoperative TR worsening.

20.
JACC Cardiovasc Interv ; 16(5): 515-526, 2023 03 13.
Artigo em Inglês | MEDLINE | ID: mdl-36922036

RESUMO

BACKGROUND: Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) may be associated with adverse hemodynamics, which might affect clinical outcomes. OBJECTIVES: This study sought to evaluate the extent and predictors of transcatheter heart valve (THV) deformity in ViV TAVR and the relation to postprocedural hemodynamics. METHODS: We examined 53 patients who underwent ViV TAVR in surgical heart valves with self-expanding Evolut prostheses. THV deformation was examined using cardiac computed tomography prospectively performed 30 days after ViV TAVR, and correlated with 30-day echocardiographic hemodynamic data. RESULTS: Near complete expansion of the functional portion of the implanted ViV prostheses (ie, >90%) was observed in 16 (30.2%) patients. Factors related to greater expansion of the functional portion and consequently larger neosinus volume were absence of polymer surgical frame, higher implantation and use of balloon aortic valvuloplasty or bioprosthetic valve fracture during the procedure (all P < 0.05). Underexpansion of the functional portion, but not the valve inflow frame, was closely associated with mean gradient and effective orifice area at 30 days on echocardiography, with and without adjustment for the sizes of the THV and surgical heart valve. CONCLUSIONS: Underexpansion of the functional portion of THV prostheses is common during ViV TAVR, occurs more frequently with deep implantation and the presence of a polymer surgical stent frame, and is associated with worse postprocedural hemodynamics. Procedural techniques, such as higher implantation and balloon postdilatation, may be used to help overcome problems with THV underexpansion and improve clinical outcomes.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Hemodinâmica , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...